VDO pressure transducer
with warning contact, via ground. For measuring gas or liquid pressure in conjunction with an electrical indicator. With these electromechanical pressure transducers, the electrical resistance of 10-184 ohms varies depending on the pressure. The warning contact closes when the pressure drops.
Measuring range: 10 bar
Warning contact / switching point: 0.5 bar ± 0.15 bar
Thread: M10 x 1 short cone
Length, L1: 19.5 mm
Length, L2: 11.0 mm
Connection: 2 knurled nut M4
Rated voltage: 6 V to 24 V
Overpressure safety: max. 30 bar or 50 bar (short-term to 2 seconds )
Warning contact: closes when pressure drops
Switching capacity of the warning contact: max. 5 W induction-free
Operating temperature: -25 ° C to +100 ° C (up to +120 ° C max. 1 hour at the connection thread)
Resistance range: 10 ? to 184 ?
Manufacturer Nr.: Continental 360-081-030-009C
EAN: 4103590690845